These are various applications of the automatic fire suppression system.
It is used as a cost-effective technical solution for automatic fire suppression in fireplaces (chimneys), in oil or natural gas central heating boiler rooms and in small vehicle garages, giving them safe fire protection not only by putting out the fire immediately but also by slowing the spread of fire across surfaces at the same time.
Its purpose is to deal with the following risks:
a. Fire breaking out because of a burner malfunction.
b. Fire breaking out because of a possible failure of the flue pipe connecting the boiler to the chimney, due to overheating caused by soot building up on its surfaces.
c. A surface fire in the liquid fuel caused by corrosion and leakage of the tank.
d. Fire breaking out in general, from overheating or an electrical short circuit in the boiler room.
Using the system is even more pressing for the automatic suppression of chimney fires in open hearths (fireplaces).
SPECIAL FEATURES
It comprises one or more standard fire extinguishing cylinders, each with a capacity of 6–12 L. The extinguishing agent is discharged under pressure into the space as droplets (water mist) and drains away after the fire has been put out, leaving no solid residue. The basic operating principle of the system is to achieve a constant working pressure by dividing the volume equally between the extinguishing liquid and the propellant gas.
For example, a cylinder with a total capacity of 12 L and an indicative initial pressure of 15 bar contains 6 L of flameout extinguishing liquid and 6 L of inert nitrogen propellant gas.
The cylinder is connected to one or more heat-sensitive nozzles that discharge droplets of extinguishing agent, with a burst temperature of 68 °C or higher.
A system with one 12 L cylinder is used successfully in boiler rooms with a total floor area of up to 15 m² and a total height of up to 4 m, with two points of fire detection and extinguishing agent discharge.
A larger system with a total of 12 L of extinguishing agent consists of two cylinders: the main cylinder contains the extinguishing agent, while the auxiliary cylinder contains inert propellant gas at an indicative initial pressure of 15 bar. This combination provides for the installation of a larger closed hydraulic network with more automatic nozzles.
A two-cylinder system is used successfully in boiler rooms with a total floor area of up to 30 m² and a total height of up to 4 m.
The heat-sensitive nozzles are preferably placed above the likely points where a fire may start, such as the burner, the boiler flue and the fuel tank area.
The system's cylinders are made of stainless steel or have strong internal anti-corrosion protection for a long service life.
They carry CE marking certification from an accredited body.
The system does not need the annual periodic recharge as long as it has not been activated, and it is designed so that it can be serviced and refilled where it is installed.
The system's excellent performance goes hand in hand with its environmentally friendly character.
The system operates automatically when the temperature limit is exceeded and the thermal bulb bursts in one or more automatic nozzles as the heat in the protected space rises.
As an option, the system has a built-in pressure switch for remote transmission of its activation signal.
In this way, the fixed automatic boiler room fire suppression system can be connected to the building's burglar alarm system for immediate notification by telephone, or to an audible and visual fire alarm device, and can also cut off the electricity supply automatically in the event of a fire.
The whole design of the fixed automatic boiler room fire suppression system described above ensures the guaranteed operation of the system and its long service life, without depending on any form of external power.
SPECIAL APPLICATION
The same system is offered for automatic fire suppression in small private car parks (garages) with a floor area of up to 300 m². In this case, a single hydraulic network is created with automatic nozzles placed 2–3 metres apart. The network is supplied by a bank of 5 standard 12 L fire extinguishing cylinders. This single system can selectively provide immediate automatic suppression of a fire spreading over an area of 20–30 m², for 3 to 10 minutes, depending on the number of automatic nozzles activated.